GUARDIAN SERIES
Residential Standby Generators
Air-Cooled Gas Engine




INCLUDES:
- True Power Electrical Technology
- Two-line multilingual digital LCD Evolution controller
- Two transfer switch options available:
- 100 amp 16 circuit switch
- or 200 amp service rated smart switch
- Electronic governor
- Standard Wi-Fi connectivity
- System status & maintenance interval LED indicators
- Sound attenuated enclosure
- Flexible fuel line connector
- Natural gas or LP gas operation
- 5 Year limited warranty
- Listed and labeled for installation as close as 18″ to a structure
- *Must be located away from doors, windows, and fresh air intakes in accordance with local codes.
FEATURES:
- Innovative engine design & rigorous testing are at the heart of Generac’s success in providing the most reliable generators possible. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions.
- Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems
- Prototype Tested
- System Torsional Tested
- NEMA MG1-22 Evaluation
- Motor Starting Ability
- Mobile Link Wifi-Connectivity – Free with select Guardian Series home standby generators. Mobile Link WiFi allows users to monitor the status of the generator from anywhere in the world using a smartphone, tablet or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service.
- Solid-state, frequency compensated voltage regulation: This state-of-the-art power-maximizing regulation system is standard on all Generac models. It provides optimized fast response to changing load conditions and maximum motor starting capability by electronically torque-matching the surge loads to the engine.
- Single source service response from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component
- The Generac product line is offered with its own transfer systems and controls for total system compatibility.
ENGINE
- Generac G-Force design maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
- “Spiny-lok” cast iron cylinder walls’ rigid construction and added durability provide long engine life.
- Electronic ignition/spark advance. These features combine to assure smooth, quick starting every time.
- Full pressure lubrication system. Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/ 200 hour oil change interval.
- Low oil pressure shutdown system. Shutdown protection prevents catastrophic engine damage due to low oil.
- EPA Certified for non-emergency applications. Allows unit to be used for demand response applications.
- High temperature shutdown prevents damage due to overheating.
GENERATOR
- Revolving field allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
- Skewed stator produces a smooth output waveform for compatibility with electronic equipment.
- Displaced phase excitation maximizes motor starting capability.
- Automatic voltage regulation. Regulating output voltage to ± prevents damaging voltage spikes
- UL 2200 listed for your safety.
TRANSFER SWITCH (IF APPLICABLE)
- Fully automatic. Transfers vital electrical loads to the energized source of power.
- NEMA 3R can be installed inside or outside for maximum flexibility.
- Remote mounting. Mounts near an existing distribution panel for simple, low-cost installation.
EVOLUTION CONTROLS
- AUTO/MANUAL/OFF illuminated buttons. Select the operating mode and provide easy, at-a-glance status indication in any condition.
- Tow-line multilingual LCD. Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.
- Sealed, raised buttons. Smooth, weather-resistant user interface for programming and operations.
- Utility voltage sensing. Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
- Generator voltage sensing. Constantly monitors generator voltage to verify the cleanest power is delivered to the home.
- Utliity interrupt delay prevents nuisance startups of the engine. Adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer
- Engine warm-up verifies engine is ready to assume the load. Set-point approximately 5 seconds.
- Engine cool-down allows engine to cool prior to shutdown. Set-point approximately 1 minute.
- Programmable exercise operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation, providing flexibility and potentially lower fuel costs to the owner.
- Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries.
- Main line circuit breaker protects generator from overload.
- Electronic governor maintains constant 60 Hz frequency.
UNIT
- SAE weather protective enclosure. Sound attenuated enclosure ensures quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
- Enclosed critical grade muffler. Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
- Small, compact, and attractive. Makes for an easy, eye-pleasing installation, as close as 18″ away from a structure.
INSTALLATION SYSTEM
- 14″ flexible fuel line connector. Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping.
- Integral sediment trap. Meets IFGC and NFPA 54 installation requirements.
CONNECTIVITY
- Ability to view generator status. Monitor your generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind
- Ability to view generator Exercise/Run and Total Hours
- Ability to view generator maintenance information. Provides maintenance information for your specific model generator when scheduled maintenance is due.
- Monthly report with previous month’s activity. Detailed monthly reports provide historical generator information.
- Ability to view generator battery information. Built-in battery diagnostics displaying current state of battery.
- Weather information. Provides detailed local ambient weather conditions for generator location.
SPECIFICATIONS


SWITCH OPTIONS


DIMENSIONS & UPCs





INCLUDES:
- True Power Electrical Technology
- Two-line multilingual digital LCD Evolution controller (English/Spanish/French/Portuguese)
- 200 amp service rated transfer switch available
- Electronic governor
- Standard Wi-Fi connectivity
- System status & maintenance interval LED indicators
- Sound attenuated enclosure
- Flexible fuel line connector
- Natural gas or LP gas operation
- 5 Year limited warranty
- Listed and labeled for installation as close as 18″ to a structure *Must be located away from doors, windows, and fresh air intakes in accordance with local codes.
FEATURES:
- Innovative engine design & rigorous testing are at the heart of Generac’s success in providing the most reliable generators possible. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions
- Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems
- Prototype Tested
- System Torsional Tested
- NEMA MG1-22 Evaluation
- Motor Starting Ability
- Mobile Link Wifi-Connectivity – Free with select Guardian Series home standby generators. Mobile Link WiFi allows users to monitor the status of the generator from anywhere in the world using a smartphone, tablet or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service.
- Solid-state, frequency compensated voltage regulation: This state-of-the-art power-maximizing regulation system is stand on all Generac models. It provides optimized fast response to changing load conditions and maximum motor starting capability by electronically torque-matching the surge loads to the engine.
- Single source service response from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component
- The Generac product line is offered with its own transfer systems and controls for total system compatibility.
ENGINE
- Generac G-Force design maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
- “Spiny-lok” cast iron cylinder walls’ rigid construction and added durability provide long engine life.
- Electronic ignition/spark advance. These features combine to assure smooth, quick starting every time.
- Full pressure lubrication system. Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/ 200 hour oil change interval.
- Low oil pressure shutdown system. Shutdown protection prevents catastrophic engine damage due to low oil.
- EPA Certified for non-emergency applications. Allows unit to be used for demand response applications.
- High temperature shutdown prevents damage due to overheating.
GENERATOR
- Revolving field allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
- Skewed stator produces a smooth output waveform for compatibility with electronic equipment.
- Displaced phase excitation maximizes motor starting capability.
- Automatic voltage regulation. Regulating output voltage to ± prevents damaging voltage spikes
- UL 2200 listed for your safety.
TRANSFER SWITCH (IF APPLICABLE)
- Fully automatic. Transfers vital electrical loads to the energized source of power.
- NEMA 3R can be installed inside or outside for maximum flexibility.
- Integrated load management technology. Capability to manage additional loads for efficient power management.
- Remote mounting. Mounts near an existing distribution panel for simple, low-cost installation.
EVOLUTION CONTROLS
- AUTO/MANUAL/OFF illuminated buttons. Select the operating mode and provide easy, at-a-glance status indication in any condition.
- Tow-line multilingual LCD. Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.
- Sealed, raised buttons. Smooth, weather-resistant user interface for programming and operations.
- Utility voltage sensing. Constantly monitors utility voltage, set-points 65% dropout, 80% pick-up, of standard voltage.
- Generator voltage sensing. Constantly monitors generator voltage to verify the cleanest power is delivered to the home.
- Utility interrupt delay prevents nuisance startups of the engine. Adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer
- Engine warm-up verifies engine is ready to the assume the load. Set-point approximately 5 seconds.
- Engine cool-down allows engine to cool prior to shutdown. Set-point approximately 1 minute.
- Programmable exercise operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation, providing flexibility and potentially lower fuel costs to the owner.
- Smart battery charger. Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries.
- Main line circuit breaker protects generator from overload.
- Electronic governor maintains constant 60 Hz frequency.
UNIT
- SAE weather protective enclosure. Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph( 241 km/h). Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
- Enclosed critical grade muffler. Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
- Small, compact, and attractive. Makes for an easy, eye-pleasing installation, as close as 18″ away from a structure.
INSTALLATION SYSTEM
- 14″ flexible fuel line connector. Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping.
- Integral sediment trap. Meets IFGC and NFPA 54 installation requirements.
CONNECTIVITY
- Ability to view generator status. Monitor your generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind
- Ability to view generator Exercise/Run and Total Hours
- Ability to view generator maintenance information. Provides maintenance information for your specific model generator when scheduled maintenance is due.
- Monthly report with previous month’s activity. Detailed monthly reports provide historical generator information.
- Ability to view generator battery information. Built-in battery diagnostics displaying current state of battery.
- Weather information. Provides detailed local ambient weather conditions for generator location.
SPECIFICATIONS


SWITCH OPTIONS

DIMENSIONS & UPCs



AC Rated Output Running Watts 8,000
AC Maximum Output Starting Watts 10,000
FEATURES
- COsense Technology – STOPS, ALERTS, SAVES. Powerful protection against hazardous carbon monoxide.
- PowerRush Advanced Technology delivers over 30% more starting capacity allowing you to do more with less. Increases electrical current upon demand; above rated output when starting electric motors.
- Electric start for easy operation (battery included)
- Generac’s OHV engine with splash lubrication provides a long engine life
- Low-oil level shutdown automatically safeguards engine from damage.
- Large-capacity steel fuel tank with incorporated fuel gauge provides durability and up to a 15 hour run-time at 25% load (10 hour run-time at 50% load.)
- 1 1/4″ steel-tube cradle for added durability and strength
- Hour Meter tracks maintenance intervals
- Heavy-duty, never-flat wheels allow for easy portability
- Fold-down locking handle for sturdy portability and compact storage
- HomeLink Manual Transfer Switch compatible. Designed to work with HomeLink manual transfer switches for safe home backup power.
CONTROL PANEL

SPECIFICATIONS

DIMENSIONS & WEIGHTS